Discover nodes using OME

Overview

The Omnia Discovery module connects to Dell OpenManage Enterprise (OME) from the Omnia Infrastructure Manager (OIM), collects server and network-interface inventory, and generates the node mapping used by the Orchestrator module. Discovery runs locally on the OIM and supports OME as its discovery mechanism.

A complete untagged run:

  1. Validates discovery_config.yml.
  2. Creates or loads the OME credentials stored for the selected project.
  3. Verifies that OME is reachable on TCP port 443.
  4. Collects OME devices of server type 1000, their iDRAC details, Ethernet interfaces, InfiniBand interfaces, and OME static-group membership.
  5. Generates a timestamped PXE mapping file and a NIC-status report.
  6. Once the OME discovery role starts, writes discovery_status.yml with the result of that role.

With the default data path and project, the generated files are under /opt/omnia/discovery/output/project_default/:

File Purpose
bmc_pxe_mapping_file_<timestamp>.csv Timestamped node mapping for review and downstream use.
bmc_pxe_mapping_file.csv Symbolic link to the latest timestamped mapping file.
bmc_discovery_report_<timestamp>.csv Point-in-time report of BMC, Ethernet, and InfiniBand NIC status.
discovery_status.yml OME role status, mapping-file path, discovered-server count, and timestamp. This file is not updated by earlier failures.

Discovery generates the mapping required by the downstream deployment workflow. It does not build OS images.

Prerequisites

  • Run Discovery on the OIM with permission to create files under the Omnia data path and /var/log/omnia/discovery/discovery.log.
  • Complete OIM setup. The main setup runs the Discovery initialization script, installs its dependencies, creates its runtime and log directories, and stages its input templates.
  • If Discovery was skipped during main setup, initialize it with ./omnia.sh --init discovery from src/main before the first run.
  • Use the module-initialized environment. requirements.txt requests Ansible Core 2.20 or later, Jinja 3.0 or later, and PyYAML 6.0.3 or later; requirements.yml requests ansible.posix 2.0.0 and community.general 10.3.0. The requests Python library must also be importable by Ansible, and openssl must be available to generate a Vault password when the credential files do not exist.
  • OME must be installed, powered on, and reachable from the OIM over HTTPS on TCP port 443.
  • Credentials for an OME administrator, or an account with equivalent permissions to create an API session and read the required inventory, must be available. Discovery prompts for missing OME credentials, saves them in discovery_credentials.yml, and encrypts the file with Ansible Vault using .discovery_credentials_key.
  • Every target server must have its BMC/iDRAC interface configured with network connectivity and must already be discovered and managed by OME as a server device. Each target must report a service tag. Devices without a service tag are not added to the discovered server list.
  • OME must expose the device, group, device-management, and server network interface inventory used by Discovery.

Network connectivity requirements

Connection Requirement
OIM to OME The OIM must be able to route to the configured ome_ip and establish an HTTPS connection on TCP port 443. Permit this outbound connection through intervening firewalls.
OME to target BMC/iDRAC Each BMC/iDRAC interface must have working network configuration and be reachable from OME. Before running Discovery, confirm that OME lists the target as a server device and displays its service tag, management address, and network-interface inventory.
OIM to target BMC/iDRAC The Discovery workflow does not connect directly to target BMC/iDRAC interfaces. It obtains their management and NIC data through the OME API. Direct or routed OIM-to-iDRAC connectivity can still be required by downstream provisioning and other Omnia operations.

The OME account must be able to create an API session and read devices, static groups and group membership, device-management details, and server network-interface inventory. OME administrative access provides these permissions. If a restricted account is used, grant equivalent read access to these resources.

The subnets in the Discovery-owned network_spec.yml are used to derive addresses written to the mapping file. They do not configure or validate the network paths between the OIM, OME, and target BMC/iDRAC interfaces. For the deployment-wide BMC network design, see Network topologies.

NIC MAC address selection

Discovery uses the interface and port order returned by the OME serverNetworkInterfaces inventory. It does not sort candidates by NIC name, slot, port number, or MAC address. Within the same priority, the first candidate returned by OME is selected. Review the NIC presentation and port ordering in OME after changing adapter, BIOS, or iDRAC configuration.

For the Admin NIC, Discovery excludes an interface whose OME NicId contains InfiniBand, using a case-insensitive comparison. A primary candidate must contain a port with at least one partition and a nonempty CurrentMacAddress; Discovery uses the first partition's current MAC address. Always verify that the generated ADMIN_MAC is the intended admin/PXE interface and is not a management interface before provisioning.

Admin NIC selection priority:

Priority Condition Selection behavior
1 At least one usable candidate that passes the current NicId filter is reported as Up Select the first Up candidate in OME inventory order. Earlier candidates reported as Down, Unknown, or another state are skipped.
2 No usable candidate is reported as Up, but the primary inventory contains a usable candidate that passes the current NicId filter Select the first such candidate in OME inventory order, regardless of its reported state. This is the fallback when all usable candidates are Down, Unknown, or another non-Up state.
3 The primary inventory contains no usable candidate Query the OME deviceNics inventory and select the first entry that passes the same NicId filter. If neither inventory supplies a usable MAC address, leave ADMIN_MAC empty. The secondary inventory does not supply the selected port's link status.

The selected Admin MAC is written to ADMIN_MAC in the PXE mapping and to ETHERNET_NIC_MAC in the discovery report. Its primary-inventory link state is written only to ETHERNET_NIC_LINK_STATUS in the report.

For InfiniBand, Discovery evaluates interfaces whose OME NicId contains InfiniBand, then evaluates their ports in the order returned by OME.

InfiniBand NIC selection priority:

Priority Condition Selection behavior
1 An InfiniBand port is reported as Up Select the first Up port in OME inventory order.
2 No port is Up, but a port is reported as Unknown or without a status Select the first such port as the fallback. A missing status is normalized to Unknown.
3 No port is Up or Unknown, but an InfiniBand port has another state such as Down Select the first port at this priority as the last resort.

If OME reports no interface whose NicId contains InfiniBand, Discovery leaves IB_NIC_NAME and IB_NIC_LINK_STATUS empty in the report and leaves IB_NIC_NAME and IB_IP empty in the mapping. This is expected for servers that do not require InfiniBand. If an interface is expected, refresh and verify the server inventory in OME before rerunning Discovery.

Input contract

Discovery resolves its runtime paths from the following values:

Input Required value or default
OMNIA_DATA_PATH Optional. Defaults to /opt/omnia.
OMNIA_PROJECT_NAME Optional. Defaults to project_default.
project_name Optional Ansible extra variable used when OMNIA_PROJECT_NAME is not set.

Prepare the following files in <OMNIA_DATA_PATH>/discovery/input/<OMNIA_PROJECT_NAME>/:

Input Requirement
discovery_config.yml Required. Contains the OME IPv4 address in ome_ip.
network_spec.yml Required during execution. Discovery reads the admin and InfiniBand subnet values from this file to derive node IP addresses.
discovery_credentials.yml Created automatically if absent. Contains ome_username and ome_password and is stored encrypted.
.discovery_credentials_key Created automatically with the credential file and stored with mode 0400.

discovery_config.yml must contain ome_ip set to a valid, non-loopback OME IPv4 address.

The credential workflow requires a nonempty OME username and password. The username must contain between 1 and 64 characters and cannot contain a backslash, single quote, double quote, or semicolon. The password must contain between 1 and 128 characters. Discovery prompts only for values that are empty or absent in the credential file.

Plan iDRAC hostnames

Discovery uses the iDRAC hostname reported by OME to derive the physical GROUP_NAME written to the PXE mapping file. Configure consistent iDRAC hostnames before running Discovery so that generated physical-group values match the intended topology.

Use the following complete naming convention when encoding the server's physical location:

idrac-<SU><1-100>R<000-999>OU<1-54><Type><Instance>
Component Description Recommended format
SU Scalable Unit containing the server. SU1 through SU100; matching is case-insensitive.
R Rack within the Scalable Unit. R1 through R999.
OU Open Rack v3 unit position within the rack. OU1 through OU54.
Type Server type at the rack position. Use C for a compute node.
Instance Individual server instance at the rack position. 1 through 99.

For example:

Example breakdown
SU02   R1   OU05   C7
│      │     │      │
│      │     │      └── Compute node instance
│      │     └───────── Open Rack v3 unit position
│      └─────────────── Rack within the Scalable Unit
└────────────────────── Scalable Unit

idrac-SU02R1OU05C7 identifies compute node 7 at unit position 5 in rack 1 of Scalable Unit 02.

The current mapping generator searches the OME-reported hostname for a case-insensitive SU[optional-letter]<digits>R<digits> sequence and writes the matched SU portion in uppercase. The complete naming convention and numeric ranges above are operational planning requirements; Discovery does not validate the entire hostname or those ranges.

OME-reported iDRAC hostname Generated GROUP_NAME
idrac-SU02R1OU05C7 SU02
idrac-SUA99R999OU30C2 SUA99
SU1R2OU1C5 SU1
idrac-JCGT033 grp0

Warning

OME can report an instrumentation name, a DNS name, or its device name for the iDRAC. Verify the value visible in OME before running Discovery. If the reported hostname does not contain a recognized SU...R... sequence, Discovery uses grp0. Review every generated GROUP_NAME before using the mapping as Orchestrator input.

Review generated parent metadata

Discovery may populate optional PARENT_SERVICE_TAG metadata in generated Slurm compute rows. This is Discovery generation behavior, not an Orchestrator grouping requirement. Orchestrator does not require a parent value or validate it against GROUP_NAME; review, edit, or clear it as appropriate.

A service Kubernetes cluster must include a version-qualified worker group, such as service_kube_node_rhel_10_0_x86_64 or service_kube_node_rhel_10_2_x86_64, in the Orchestrator PXE mapping. The cluster-wide minimum also includes three version-qualified service_kube_control_plane_rhel_10_<minor>_x86_64 servers. Use the same catalog-selected minor version for every Kubernetes node. For the complete service-cluster requirements, see Kubernetes requirements and Deploy Service Kubernetes.

Warning

Review every generated parent value before copying the mapping to the Orchestrator input directory. Discovery-generated parent metadata does not create an Orchestrator validation requirement.

Plan OME static groups

When OME exposes a Static Groups container, Discovery uses its immediate child groups as functional-group assignments. If that container is absent, Discovery falls back to non-system OME groups. A server can belong to no more than one of the groups that Discovery processes; Discovery stops if a server belongs to multiple processed groups.

In Omnia 2.3, OME static groups must follow the version-qualified pattern:

<prefix>_rhel_<major>_<minor>_<arch>

Where <arch> is x86_64 or aarch64. The mapping generator accepts these exact, case-sensitive OME static-group names:

  • service_kube_control_plane_rhel_10_0_x86_64
  • service_kube_node_rhel_10_0_x86_64
  • login_node_rhel_10_0_x86_64
  • login_node_rhel_10_0_aarch64
  • login_compiler_node_rhel_10_0_x86_64
  • login_compiler_node_rhel_10_0_aarch64
  • slurm_control_node_rhel_10_0_x86_64
  • slurm_node_rhel_10_0_x86_64
  • slurm_node_rhel_10_0_aarch64
  • os_rhel_10_0_x86_64
  • os_rhel_10_0_aarch64

For RHEL 10.2, use the corresponding version (e.g., slurm_node_rhel_10_2_x86_64).

Create OME static groups

Create one static group for each Omnia functional group required by the cluster:

  1. In the OME left navigation menu, select CUSTOM GROUPS > Static Groups.
  2. Select the ellipsis (...) next to Static Groups, and then select Create Group.
  3. Enter one of the supported functional-group names exactly as listed above, using the version-qualified pattern that matches your catalog.
  4. Enter a description that identifies the purpose of the group.
  5. Select Finish.

Repeat these steps for each functional group required by the cluster. The group name determines the value written to FUNCTIONAL_GROUP_NAME; the group description does not affect Discovery behavior.

Use version-qualified group names

OME static groups must use the version-qualified pattern <prefix>_rhel_<major>_<minor>_<arch>. Discovery uses the OME static-group name directly as the functional group. Ensure the OME group names match the functional groups defined in the catalog used by Orchestrator.

Assign devices to OME static groups

After creating the required static groups, assign the discovered servers:

  1. Select the static group from the OME group list.
  2. Select Add Devices.
  3. In the Add Devices to Group dialog box, select the servers whose intended role matches the functional group.
  4. Select Finish.

Repeat these steps for the remaining groups. Before running Discovery, verify that each server is assigned to no more than one Omnia static group and that each group is an immediate child of Static Groups.

A server without a static-group assignment is placed in the default functional group slurm_node_rhel_10_0_aarch64. A server assigned to a nonempty, unsupported static group is also placed in the default functional group with a warning; the server is not skipped and appears in the mapping file.

For slurm_node_rhel_10_0_x86_64 and slurm_node_rhel_10_0_aarch64, Discovery may populate optional PARENT_SERVICE_TAG metadata. Review, edit, or clear that value as appropriate before using the mapping as Orchestrator input.

Procedure

  1. In OME, discover or manage the target servers that Omnia will provision. Confirm that each target appears in OME as a server device and has a service tag, an iDRAC management address, and the expected network-interface inventory. Confirm that the account used by Discovery can view these details. Omnia queries the existing OME inventory; it does not add devices to OME. For the version-specific device-discovery procedure, see the Dell OpenManage Enterprise documentation.

  2. Configure the Main environment. The examples on this page use OMNIA_DATA_PATH=/opt/omnia and OMNIA_PROJECT_NAME=project_default.

  3. Complete OIM setup. If Discovery was skipped during setup, initialize only this domain:

    Run on: OIM host
    cd src/main
    ./omnia.sh --init discovery
    

    Initialization installs the declared dependencies, creates the runtime and log directories, and copies discovery_config.yml and network_spec.yml to <OMNIA_DATA_PATH>/discovery/input/<OMNIA_PROJECT_NAME>/. Review its output and confirm that the dependencies are available.

    Warning

    If the destination already contains files, initialization asks before overwriting them. Preserve any project-specific changes when responding to the prompt.

  4. Create the required OME static groups, and then assign the discovered servers. Use an exact supported functional-group name and place each server in no more than one Omnia static group. A server without a static-group assignment uses the default functional group (slurm_node_rhel_10_0_aarch64).

  5. Edit the staged discovery_config.yml and configure the OME appliance:

    File: /opt/omnia/discovery/input/project_default/discovery_config.yml
    ome_ip: "192.168.1.100"
    

    Configure ome_ip with a valid, non-loopback OME IPv4 address, which is the format defined by the Discovery configuration schema.

  6. Edit the staged network_spec.yml. Discovery validates this file against the same JSON schema used by Orchestrator, so all required fields must be present. Discovery uses admin_network.subnet and ib_network.subnet for IP derivation.

    File: /opt/omnia/discovery/input/project_default/network_spec.yml
    Networks:
      - admin_network:
          oim_nic_name: "eno1"
          subnet: "172.16.0.0"
          netmask_bits: "24"
          primary_oim_admin_ip: "172.16.107.254"
          primary_oim_bmc_ip: ""
          router: "172.16.107.254"
          dynamic_range: "172.16.107.201-172.16.107.250"
          dns: []
          ntp_servers: []
          additional_subnets: []
    
      - ib_network:
          subnet: "192.168.0.0"
          netmask_bits: "24"
          dns: []
    

    Discovery derives ADMIN_IP by combining the first two octets of the admin subnet with the last two octets of the server's BMC IP. It derives IB_IP in the same way from the InfiniBand subnet, but only when an InfiniBand NIC was detected.

  7. Validate discovery_config.yml and network_spec.yml before contacting OME:

    Run on: OIM host
    cd <OMNIA_SOURCE_PATH>/src/main
    ./omnia.sh --run discovery --tags validate
    
    Run on: OIM host
    source /opt/omnia/activate-omnia.sh
    cd <OMNIA_SOURCE_PATH>/src/discovery/playbooks
    ansible-playbook discovery.yml --tags validate
    

    The validate phase performs JSON schema validation on both input files:

    File Schema Validation
    discovery_config.yml discovery_config.json Validates ome_ip is a valid, non-loopback IPv4 address
    network_spec.yml network_spec.json Validates against the same schema used by Orchestrator

    A successful validation prints Discovery configuration validation passed. and displays the validation-log path. This phase does not request OME credentials.

  8. Run the complete Discovery workflow:

    Run on: OIM host
    cd <OMNIA_SOURCE_PATH>/src/main
    ./omnia.sh --run discovery
    
    Run on: OIM host
    source /opt/omnia/activate-omnia.sh
    cd <OMNIA_SOURCE_PATH>/src/discovery/playbooks
    ansible-playbook discovery.yml
    

    When discovery_credentials.yml does not exist, Discovery creates it and creates its Vault key if needed. Enter the OME username and password when prompted. The password prompt asks for confirmation before the credential file is encrypted.

    The default untagged run performs setup, validation, credential handling, and OME discovery. The execute and discovery tags route to the same OME execution flow. The credentials tag updates credentials without running discovery. Use only one tag in a command. See Run Discovery for the complete tag table, including the supported precheck, cleanup operations, and lifecycle placeholders.

    The supported Discovery execution flow uses OME. The playbook sets discovery_mechanism to ome internally; do not pass -e discovery_mechanism=ome.

Expected completion output

A successful run without BuildStreaM prints a completion summary in this form:

Representative success output
============================================================
OME Discovery Complete
============================================================
BMC PXE mapping file generated: /opt/omnia/discovery/output/project_default/bmc_pxe_mapping_file_<timestamp>.csv
BMC discovery report generated: /opt/omnia/discovery/output/project_default/bmc_discovery_report_<timestamp>.csv
  (Lists link status of BMC, Ethernet, and InfiniBand NICs for each server)
Total servers discovered: <count>

Output directory: /opt/omnia/discovery/output/project_default

Next Steps:
1. Review and edit the generated PXE mapping file.
2. Review the discovery report for NIC link statuses.
3. Update HOSTNAME, FUNCTIONAL_GROUP_NAME, GROUP_NAME as needed.
4. Copy the mapping file to the Orchestrator input directory.
============================================================

The current Discovery implementation may print a BuildStreaM-specific completion message only when a build_stream_config.yml is present in the Discovery input directory. That file is not part of the Discovery input contract. Follow the BuildStreaM handoff in Next steps instead of copying another domain's configuration into this directory.

BMC discovery report

Discovery generates a read-only CSV report from the OME inventory for every discovered server that has a service tag. The report provides a point-in-time view of the BMC, selected Ethernet, and selected InfiniBand interfaces and their OME-reported link states. Review it before provisioning to identify missing inventory or connectivity that can prevent management access or PXE boot.

Report location

The report is written to the Discovery-owned project output directory:

<OMNIA_DATA_PATH>/discovery/output/<OMNIA_PROJECT_NAME>/bmc_discovery_report_<timestamp>.csv

With the standard data path and project name, the location is:

/opt/omnia/discovery/output/project_default/bmc_discovery_report_<timestamp>.csv

The timestamp matches the timestamped PXE mapping generated by the same run. Unlike the mapping, the report does not have a stable symbolic link. Use the path printed in the completion output or substitute the mapping timestamp when opening the report.

Report columns

Column Description
SERVICE_TAG Dell service tag used to correlate the row with the physical server, OME inventory, and PXE mapping.
BMC_MAC MAC address from the server's OME iDRAC management record.
BMC_IP IP address from the server's OME iDRAC management record.
BMC_NIC_STATUS Up when Discovery finds an iDRAC management record. This value represents OME inventory availability; it is not a live reachability test from the OIM.
ETHERNET_NIC_MAC MAC address of the selected interface that passes the current NicId filter. Discovery excludes InfiniBand labels, prefers the first usable interface reported as Up, and then falls back to the first usable interface. Confirm that this is the intended admin/PXE interface and not a management interface.
ETHERNET_NIC_LINK_STATUS OME-reported link state of the Ethernet interface selected for ETHERNET_NIC_MAC.
IB_NIC_NAME OME identifier for the selected InfiniBand port. Empty when OME reports no InfiniBand interface.
IB_NIC_LINK_STATUS OME-reported link state of the selected InfiniBand port. Empty when no InfiniBand interface is selected.

Sample report

Illustrative bmc_discovery_report_<timestamp>.csv
SERVICE_TAG,BMC_MAC,BMC_IP,BMC_NIC_STATUS,ETHERNET_NIC_MAC,ETHERNET_NIC_LINK_STATUS,IB_NIC_NAME,IB_NIC_LINK_STATUS
H94M8F3,B8:CE:F6:57:89:D0,172.16.0.101,Up,B0:7B:25:D8:4A:F4,Up,InfiniBand.Slot.3-1,Unknown
J7KN2G4,A4:BF:01:12:34:56,172.16.0.102,Up,E4:43:4B:01:23:45,Up,,
K5LP9H2,D0:94:66:AB:CD:EF,172.16.0.103,Up,24:6E:96:78:90:12,Unknown,InfiniBand.Slot.3-1,Up

The values are examples only. Compare each row with the corresponding server and current OME inventory.

  • BMC: A value of Up means that Discovery found an iDRAC management record in OME. Confirm BMC connectivity in OME or with an approved network test when current reachability must be established. An empty value indicates that the required management record was not returned.
  • Ethernet: Up indicates that OME reports a link for the selected Ethernet port. Down generally indicates no active physical link. Unknown means that OME did not provide a definitive state. When no usable Ethernet port is reported as Up, Discovery records the first usable candidate that passes the current NicId filter as a fallback. Confirm the selected MAC is the intended admin/PXE interface.
  • InfiniBand: Discovery prefers a port reported as Up, then Unknown, then another reported state such as Down. An Unknown state can occur even when the fabric becomes available at the operating-system level. Confirm the fabric independently before provisioning workloads that require it.

Pre-provisioning checks

Before copying the mapping to the Orchestrator input directory:

  1. Confirm that every expected service tag appears in the report.
  2. Confirm that BMC_IP and BMC_MAC match the intended server's iDRAC inventory.
  3. Confirm that ETHERNET_NIC_MAC is the interface connected to the admin/PXE network and investigate Down, Unknown, or empty link states.
  4. Confirm that servers requiring InfiniBand have an IB_NIC_NAME, and investigate an unexpected or empty link state.
  5. Compare the report and mapping rows by SERVICE_TAG, using files with the same timestamp.

Troubleshoot NIC connectivity

If the expected interface is missing or has an unexpected state:

  1. Locate the server by SERVICE_TAG in the report and inspect the BMC, Ethernet, and InfiniBand fields together.
  2. In OME, refresh the server inventory and confirm the iDRAC management record, NIC ordering, current MAC addresses, and port link states.
  3. For an Ethernet state of Down or Unknown, inspect the cable, switch port, and server BIOS/iDRAC NIC settings. Confirm that the intended admin/PXE port is enabled and connected.
  4. For an InfiniBand state of Down or Unknown, inspect the adapter, cable, fabric port, and fabric configuration. Validate the link at the operating system when OME cannot determine its state.
  5. Rerun Discovery after OME shows the corrected inventory, then review the newly timestamped report and mapping together.

For selection-specific guidance, see The admin MAC address is unexpected or empty and InfiniBand fields are empty.

Relationship to the PXE mapping

Attribute PXE mapping file BMC discovery report
Purpose Reviewed input handed to Orchestrator for provisioning Diagnostic and inventory snapshot used before provisioning
Rows Servers in supported OME static groups, plus unassigned servers Every discovered OME server that has a service tag
Editable Review and correct values before the Orchestrator handoff No; retain as a read-only record of the OME inventory
NIC link status Not included Includes BMC, selected Ethernet, and selected InfiniBand status
IP addresses Includes ADMIN_IP, BMC_IP, and IB_IP Includes BMC_IP only
Hostname Includes the generated HOSTNAME Not included
Downstream use Copied to the Orchestrator input project as pxe_mapping_file.csv Not consumed by Orchestrator

Verification

  1. Output contract: After a successful OME discovery, confirm that the project output directory, <OMNIA_DATA_PATH>/discovery/output/<OMNIA_PROJECT_NAME>/, contains the following artifacts:

    Artifact Verification
    bmc_pxe_mapping_file_<timestamp>.csv Timestamped PXE mapping containing discovered servers whose OME static-group assignment is supported or empty.
    bmc_pxe_mapping_file.csv Symbolic link to the latest timestamped mapping file.
    bmc_discovery_report_<timestamp>.csv NIC-status report generated from every discovered server that has a service tag.
    discovery_status.yml Status of the OME discovery role, mapping-file path, discovered-server count, and timestamp.

    With the standard data path and project name, check the status file:

    Run on: OIM host
    cat /opt/omnia/discovery/output/project_default/discovery_status.yml
    

    A successful status file has this structure:

    Expected structure
    overall_status: "success"
    discovery_mechanism: "ome"
    bmc_pxe_mapping_file: "/opt/omnia/discovery/output/project_default/bmc_pxe_mapping_file_<timestamp>.csv"
    servers_discovered: <count>
    timestamp: "<ISO 8601 timestamp>"
    

    Confirm that overall_status is success, discovery_mechanism is ome, bmc_pxe_mapping_file identifies the timestamped mapping file, and servers_discovered matches the OME servers expected in the discovery report. Setup, validation, and credential failures occur before this status file is updated; for those failures, use the Ansible output and log instead of relying on an existing status file.

  2. Confirm that the stable mapping-file link resolves to the latest timestamped file:

    Run on: OIM host
    readlink /opt/omnia/discovery/output/project_default/bmc_pxe_mapping_file.csv
    
  3. Review the generated mapping:

    Run on: OIM host
    cat /opt/omnia/discovery/output/project_default/bmc_pxe_mapping_file.csv
    

    The mapping contains these columns:

    Column Generated value
    FUNCTIONAL_GROUP_NAME Supported OME static-group name, or slurm_node_rhel_10_0_aarch64 when the server has no assignment or has an unsupported group.
    GROUP_NAME SU identifier derived from the iDRAC hostname, or grp0 when no identifier is found.
    SERVICE_TAG Service tag reported by OME.
    PARENT_SERVICE_TAG Optional parent-node service tag that Discovery may populate for a Slurm compute row; otherwise empty. Review this value before using the mapping.
    HOSTNAME nid plus a three-digit sequence number based on discovery order. The supported range is nid000 through nid999; automatic generation normally begins with nid001, and skipped devices can create gaps.
    ADMIN_MAC MAC of the first candidate that passes the current NicId filter and has link status Up; otherwise the first usable candidate that passes the filter. Confirm that this is the intended admin/PXE interface and not a management interface.
    ADMIN_IP Admin subnet's first two octets combined with the BMC IP's last two octets.
    BMC_MAC iDRAC MAC address reported by OME.
    BMC_IP iDRAC IP address reported by OME.
    IB_NIC_NAME InfiniBand port identifier selected with priority Up, then Unknown, then another reported state; empty when no InfiniBand NIC is found.
    IB_IP InfiniBand subnet's first two octets combined with the BMC IP's last two octets; empty when no InfiniBand NIC is found.
  4. Server attribute checklist: Use SERVICE_TAG to correlate every mapping row with the physical server and its OME inventory. Confirm the following values before handing the mapping to Orchestrator:

    Attribute Confirmation
    Server coverage Every expected service tag occurs exactly once. Investigate an absent server in the discovery report and its OME static-group assignment.
    FUNCTIONAL_GROUP_NAME The value is the server's intended Omnia role and exactly matches a supported, case-sensitive functional-group name. An unassigned OME server defaults to slurm_node_rhel_10_0_aarch64; retain that default only when it is the intended role.
    ADMIN_MAC The value is nonempty, unique, and matches the Ethernet port that the server will use on the admin/PXE network. Compare it with the OME interface inventory and ETHERNET_NIC_MAC in the discovery report. Prefer a port whose reported link status is Up.
    BMC_IP The value is nonempty and matches the iDRAC management address reported for that service tag in OME. Discovery copies this value from OME; it does not confirm that the address is correct for the physical server.
    HOSTNAME The value is unique and matches the deployment's hostname plan. Discovery generates a three-digit nid sequence beginning with nid001; edit the value when the generated assignment is not the intended one.

    Warning

    A generated mapping can contain syntactically valid values that do not match the intended physical server or deployment role. Correct the reviewed mapping before copying it to the Orchestrator input directory.

  5. Review the report with the same timestamp as the mapping file. Replace <timestamp> with the value in the mapping filename:

    Run on: OIM host
    cat /opt/omnia/discovery/output/project_default/bmc_discovery_report_<timestamp>.csv
    

    The report contains SERVICE_TAG, BMC_MAC, BMC_IP, BMC_NIC_STATUS, ETHERNET_NIC_MAC, ETHERNET_NIC_LINK_STATUS, IB_NIC_NAME, and IB_NIC_LINK_STATUS. Use it to identify missing NIC inventory and links reported as Down or Unknown before using the mapping downstream.

    The report includes every discovered server with a service tag. The mapping can contain fewer rows when a server was assigned to an unsupported OME static group. See BMC discovery report for the column definitions, status interpretation, pre-provisioning checks, and troubleshooting procedure.

Next steps

  1. Review and, where necessary, edit HOSTNAME, FUNCTIONAL_GROUP_NAME, and GROUP_NAME in the timestamped mapping file. Also confirm the generated service tags, optional parent metadata, MAC addresses, and IP addresses.

  2. Without BuildStreaM, copy the reviewed mapping to the Orchestrator input directory:

    Run on: OIM host
    source /etc/profile.d/omnia-env.sh
    discovery_path="${OMNIA_DATA_PATH}/discovery"
    orchestrator_path="${OMNIA_DATA_PATH}/orchestrator"
    cp "${discovery_path}/output/${OMNIA_PROJECT_NAME}/bmc_pxe_mapping_file.csv" \
      "${orchestrator_path}/input/${OMNIA_PROJECT_NAME}/pxe_mapping_file.csv"
    
  3. With BuildStreaM enabled, build the images through the build pipeline first. If the GitLab server is not yet available, place the reviewed mapping at the Orchestrator input path shown above. If GitLab is available, copy it to input/orchestrator/pxe_mapping_file.csv in the GitLab project and commit the change; the commit triggers the deploy pipeline for the nodes in that mapping.

Troubleshooting

Discovery configuration validation fails

  • Confirm that <OMNIA_DATA_PATH>/discovery/input/<project>/discovery_config.yml exists and contains ome_ip set to a valid, non-loopback OME IPv4 address.
  • Correct YAML parsing errors reported by the playbook.
  • Review /var/log/omnia/discovery/discovery.log, then rerun the validate tag.

OME is unreachable

Discovery waits up to 30 seconds for <ome_ip>:443. Confirm that ome_ip is correct, OME is powered on, and routing and firewall rules allow the OIM to reach OME on TCP port 443.

From the OIM, test the same HTTPS endpoint used to create an OME API session:

Run on: OIM host
curl --insecure --silent --show-error --connect-timeout 10 \
  --output /dev/null --write-out "HTTP status: %{http_code}\n" \
  https://<ome-ip>/api/SessionService/Sessions

An HTTP status confirms that the OIM reached the OME web service. An HTTP status such as 401 only indicates that this unauthenticated connectivity test was rejected as expected. An HTTP status: 000, timeout, connection refusal, or TLS error indicates that the OIM did not complete the HTTPS request; check the address, route, firewall, OME service, and certificate configuration.

Warning

Do not add an OME username or password to this command. Discovery obtains credentials from the Vault-encrypted project credential file.

Review the Discovery log for the port check or API error:

Run on: OIM host
tail -n 100 /var/log/omnia/discovery/discovery.log

OME authentication fails

Correct the ome_username and ome_password values managed in discovery_credentials.yml before running Discovery again. Rerunning alone does not replace nonempty stored credentials. If the credential file is Vault-encrypted, its matching .discovery_credentials_key must be present in the same project input directory. Confirm that the OME account can create an API session and read the required device, group, management, and interface inventory.

No servers are discovered

Confirm that OME manages the target devices as server type 1000 and that the devices have nonempty service tags. Discovery fails when the filtered server list is empty.

BMC or iDRAC information is missing

Confirm that the target BMC/iDRAC interface has working network connectivity and that OME can manage it. In OME, verify that the server exposes its iDRAC management address, MAC address, and server network-interface inventory. Discovery reads these values from OME and does not probe the target iDRAC directly.

A server belongs to multiple OME static groups

Discovery reports each conflicting service tag and its groups, then stops. Remove the duplicate static-group memberships so that each server belongs to no more than one static group and rerun Discovery.

A server is missing from the mapping

Look for a warning that names an unsupported OME static group. The server is automatically assigned to the default functional group (slurm_node_rhel_10_0_aarch64) with a warning. Rename the group to one of the supported functional-group names if you want a specific assignment, or leave it to use the default. The server remains visible in the discovery report if OME supplied its service tag.

The admin MAC address is unexpected or empty

  1. Find the server by service tag in the timestamped discovery report and check its ETHERNET_NIC_MAC and ETHERNET_NIC_LINK_STATUS values.
  2. In OME, inspect the server network-interface inventory. Verify the NIC ordering, the port state, and the current MAC address reported for each Ethernet interface. Discovery excludes InfiniBand-labelled interfaces and selects the first usable candidate reported as Up. Confirm the selected MAC is the intended admin/PXE interface and not a management interface.
  3. If the intended port is Down or Unknown, check its cable, switch port, and server BIOS/iDRAC NIC settings. If no usable Ethernet port is Up, Discovery falls back to the first usable candidate that passes the current NicId filter in the OME inventory.
  4. Refresh the server inventory in OME, verify that the updated port order, link state, and MAC address are visible, and rerun Discovery.

If the primary server network-interface inventory produces no MAC address, Discovery attempts the OME deviceNics inventory as a final fallback. A blank ADMIN_MAC after the OME inventory is refreshed indicates that neither inventory returned a usable Ethernet MAC address.

InfiniBand fields are empty

This is expected when OME does not report an interface whose identifier contains InfiniBand. When an interface is present, Discovery prefers an Up port, then Unknown, and then another reported state.

Group names or parent service tags are incorrect

The generated HOSTNAME and the OME-reported iDRAC hostname serve different purposes. Discovery generates HOSTNAME as an nid sequence. It uses the iDRAC hostname reported by OME only to derive GROUP_NAME.

  1. In OME, inspect the iDRAC instrumentation name, DNS name, or device name displayed for the server. Discovery uses the first available value in that order.
  2. Ensure that the value contains an SU identifier immediately followed by an R and rack number, such as SU1R2OU1C5. If no recognized SU...R... sequence is present, Discovery assigns grp0.
  3. Correct the iDRAC hostname, refresh the server inventory in OME, and rerun Discovery. See Plan iDRAC hostnames for the complete convention.
  4. Review and, if necessary, edit the generated HOSTNAME, GROUP_NAME, and PARENT_SERVICE_TAG before copying the mapping to the Orchestrator input directory. Orchestrator does not require PARENT_SERVICE_TAG or validate it against GROUP_NAME.

OME discovery execution fails

If OME execution started, inspect discovery_status.yml; a failed OME phase records failed_task and failure_reason. Setup, validation, or credential failures can leave that file absent or unchanged from a previous run. For all phases, inspect the Ansible output and /var/log/omnia/discovery/discovery.log.